Print

OMICRON products

OMICRON products comprise Level Alarm Systems, Water Ingress Systems, Gas Alarm Systems, Vapour Alarm Systems, Multi Alarm Systems and various products, including Calibration Equipment, Personal Multi-Gas Monitors, plus Alarm Lights and Alarm Horns.

Level Alarm System Type
OAS-5

Level Alarm System - Type OAS-5

For high level and overfill

OAS 5 with sensors, is a complete level alarm system required either as an independent Overfill or High level and Overfill system on all type of tankers. When delivered as a dual point system it is approved as two independent systems as required in the regulations.

OAS.5 datasheet

Vapour Alarm System
Type OVS 2.1

Vapour alarm system – Type OVS 2.1

For vapour return lines on tankers

Vapour alarm system OVS 2.1 OP monitors the oxygen content and the pressure in the waste vapour line(s) during loading of tank vessels. It consists of a detector cabinet mounted on deck with Eex ia approved oxygen and pressure sensors, flow fail initiator, manifold selector, test and purge facility. The electronic cabinet mounted in the cargo control room with alarm panel has individual LED displays and alarm status LEDs. Different models cover all configurations of manifolds and vapour lines.

OVS 2.1 OP datasheet

Gas Sampling System
Type OGS 3.1 and
OGS 3.11

Gas sampling system – Type OGS 3.1 and OGS 3.11

For total solutions in gas sampling

OGS 3.1 is our advance model for special requirements. Different models and options cover most applications you will find onboard any kind of tankers with special needs. All delivered parts are completely assembled ready for interconnection to on-site application. OGS 3.1 is based on a scanning method, which means that sample points are being connected to sensor(s) in a cyclic sequence. The operator panel has LCD display and individual LED lamps indicating each measuring point status. To minimize scanning cycle time and guarantee fresh samples at all times, the system has two vacuum pumps. One main pump, continuously sucking from all sample points and a smaller sample pump taking samples from the actual point according to the sequence. This insures quick response if gas is detected. Purging of sample line is done immediately after each sampling is finished.

OGS 3.1 datasheet
OGS 3.11 datasheet

Fixed Gas Detection
System
Type OGS 2.1

Fixed gas detection system - Type OGS 2.1

For cargo pump room and other
applications and type of vessels

Gas Alarm OGS 2.1 is a fixed detection system for pump rooms, AC inlets (ISGOTT 5th edition) and other areas. The sensors are based on Eex D approval. Most common gas sensor types are hydrocarbon, oxygen and hydrogen-sulphide. The system can independently handle infinite number of sensors. Each alarm unit have individual display, 4 adjustable independent alarm setpoints and posibilities for voting. Furthermore, each alarm unit has separate alarm LEDS for system/sensor failures.

Gas Alarm OGS 2.1 is a micro controller based gas detection system for pump rooms. The system is complete with sensors and connection points. The OGS 2.1can be delivered as a split version with the alarm panel mounted in a separate cabinet.

The alarm panel has individual displays for each sensor.
Each display has four alarm LEDs for indication of gas alarm levels and one LED for system failure alarms. The system will be factory set to give alarm at a specific gas level, but can easily be set to other levels without any instruments.

Standard configuration has potential free relay output contacts for power failure, common system failure and gas alarm. The system can also be delivered with a bridge remote alarm unit.

 OGS 2.1 datasheet

Multi Alarm System 
Type AU 2.1

Multi alarm System - type au 2.1

For high level and overfill

Base function same as for OGS 2.1 but other sensors monitored. Measurement of temperature for any machinery, motors, pumps and tank's. Different sensor types and temperature ranges are available for both hazardous and non-hazardous installations.

Pressure sensors for cargo tanks Ex area monitors the over or under-pressure in the cargo tanks. Any number of tanks can be monitored.

These two systems can also be combined in the same OGS 2.1 cabinet. Other type of sensors and applications available on request.

AU 2.1 datasheet

Water Ingress System
Type OAS WI datasheet

Water Ingress System OAS WI

For high level and overfill

Water Ingress System OAS WI has been specially designed and manufactured for detecting the presence of water in the inner bottom in any holds reaching a height of 0,5m and another height of not less than 15% of the depth of hold but not more than 2m.
Furthermore, also holds located partially or totally forward of the foremost cargo hold, and ballast tanks located forward of the foremost cargo hold, collision bulkhead of Bulk carrier, in conformity with SOLAS regulation XII/12 rule requirement.

OAS WI datasheet
Impact Personal
Multi-Gas Monitor

various products

Impact Personal Multi-gas Monitor

Portable multi-gas monitor for the protection of personnel from up to four hazardous gases simultaneously in the working environment.
Portable multi-gas monitor for the use onboard tankers for measuring the flammable gas concentration in VOL % and Oxygen level simultaneously in the working environment.
IMPACT PERSONAL MULTI-GAS MONITOR

Pressure Calibrator
Type OTE-P202 and
OTE-P300
Type OTE-P300

Temperature Calibrator

Portable temperature calibrator for testing of temperature- sensors, indicators, switches and safety equipment. The heating medium is hot air. This makes it clean to use and it has quick temperature change response. Temperature range is about 10 degrees above ambient to + 700 degrees Celsius with digital readout of the measured temperature. The calibrator is type approved by DnV. TYPE OTE-T700

Calibrator datasheet

Pressure Calibrator
Type OTE-P202 and
OTE-P300
Type OTE-P300

Pressure Calibrators

Portable pressure calibrators for testing of pressuresensors, indicators, switches and safety equipment. The pressure medium is oil. It has fine adjustment of the pressure, and an overpressure relief valve. The digital readout can be selected to bar or PSI. Pressure range is 0 - 200 bar / 0-300 bar. The unit can also be delivered in Eex version.
TYPE OTE-P202 and OTE-P300
TYPE OTE-P300

, Calibrator datasheet 

Low Pressure Vacuum
Calibrator Type LPT 1
Medium Pressure Vacuum
Calibrator
Type TP 1

Low Pressure / Medium Pressure Calibrators

Portable low pressure calibrator for testing of pressure- sensors, indicators, switches and safety equipment at a low pressure range.The calibrator can be delivered with either analogue or digital gauges. Kindly specify what type upon request and ordering.
TYPE LPT 1
TYPE TP 1

Calibrator datasheet

Alarm Light
Type OAL-A2

Alarm Lights

Alarm Light OAL -A2 is an alarm light designed for harsh outdoor mounting. The housing is of welded stainless steel. The lens is of polycarbonate and has an O-ring gasket to the housing. The electronic card is completely encapsulated in silicone rubber for moisture and vibration protection. The lower part of the housing functions as a junction box for cable connection.
This construction is especially suitable for marine applications.
TYPE OAL-A2

EEx Alarm Light
Type XB-11

Alarm Light XB-11 is an alarm light designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of UV stable glass reinforced polyester. This light is approved for connection (Eex approved connection) directly in hasardious area.
TYPE XB-11

EEx Alarm Light
Type XB-9

Alarm Light XB-9 is an alarm light designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of UV stable glass reinforced polyester.
TYPE XB-9

EEx Alarm Horn
Type DB-3

Alarm Horns

EEx Alarm horn DB-3 is an electrical alarm horn designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of reinforced polyester. Mounting bracket is included.
TYPE DB-3

Alarm Horn
Type KTV 75/400

Alarm horn KTV 75/400 is an air driven alarm horn designed for use in potentially explosive atmospheres and harsh environmental conditions. The horn is delivered with mounting bracket, soleniod valve and air filter. The solenoid valve is non-EEx and must be mounted indoor, safe area.
TYPE KTV 75/400

Alarm Horn
Type A121

Alarm horn A121 is an electrical alarm horn with very high output sounder.
TYPE A121

Alarm Horn Type A105

Alarm horn A105 is an electrical alarm horn.
TYPE A105

Contact us

Autronica Fire and Security AS
P.O. Box 5620
NO-7483 Trondheim
Norway
Phone: +47 90 90 55 00
Support: +47 915 09753

info@autronicafire.no